2 INSTALLATION MECHANICAL HF SSB TRANSMITTER T2130
In the Service Programmes the measured ‘+24V Sense’ is converted to voltage and read out to the display
on the RE2100.
The relation between the battery voltage and the ‘+24V Sense’ is determined empirical and is given by
the following equation:
‘+24V Sense’ + Cal_offset = Vbattery * 1.31 - 0.95 (Volt)
giving:
’24V Sense’ + Cal_offset + 0.95
Vbattery = ----------------------------------------- (Volt)
1.31
9315