L
Luis FrankAug 31, 2025
What does 'Bat Volt.High Err' mean on my SAJ H1-6K-S2 Inverter?
- XxhillAug 31, 2025
The 'Bat Volt.High Err' on your SAJ Inverter indicates a battery over-voltage condition.
What does 'Bat Volt.High Err' mean on my SAJ H1-6K-S2 Inverter?
The 'Bat Volt.High Err' on your SAJ Inverter indicates a battery over-voltage condition.
What does 'PV2 Curr.High Err' mean on my SAJ H1-6K-S2?
The 'PV2 Curr.High Err' on your SAJ Inverter indicates PV2 over-current.
What does 'PV1 Curr.High Err' mean on my SAJ H1-6K-S2?
The 'PV1 Curr.High Err' on your SAJ Inverter indicates PV1 over-current.
What does 'Inv Curr.High Err' mean on my SAJ H1-6K-S2 Inverter?
The 'Inv Curr.High Err' on your SAJ Inverter indicates an inverter over-current situation.
What does 'PV2 Volt.High Err' mean on my SAJ H1-6K-S2 Inverter?
The 'PV2 Volt.High Err' on your SAJ Inverter means there is PV2 over-voltage.
What does 'PV1 Volt.High Err' mean on my SAJ H1-6K-S2 Inverter?
The 'PV1 Volt.High Err' on your SAJ Inverter means there is PV1 over-voltage.
What does 'GFCI Err' mean on my SAJ Inverter?
If your SAJ Inverter displays 'GFCI Err', this indicates a GFCI error.
What does 'Temp.High Err' mean on SAJ H1-6K-S2 Inverter?
If your SAJ Inverter displays 'Temp.High Err', this indicates a high temperature issue.
Number of MPP Trackers | 2 |
---|---|
THDi | < 3% |
European Efficiency | 97.5% |
Protection Degree | IP65 |
Cooling Method | Natural convection |
Rated Power | 6 kW |
Rated AC Output Power | 6 kW |
Rated AC Voltage | 230 V |
AC Voltage Range | 180 V - 280 V |
Rated Grid Frequency | 50 Hz / 60 Hz |
DC Switch | Yes |
Operating Temperature Range | -25°C to 60°C |
Communication | WiFi |
Operating Temperature | -25°C to 60°C |
Humidity | 0-100% |
Explains hazard symbols (Danger, Warning, Caution, Notice) and their meanings.
Lists critical safety warnings related to electrical shock, high voltage, and environmental conditions.
Provides comprehensive technical specifications, including input/output data and protection features.
Outlines essential safety precautions to be followed before and during inverter installation.
Emphasizes safety protocols for technicians performing electrical connections on live equipment.
Guides users through initial system configuration, time setting, and country selection.
Lists and explains fault codes and types for the master device.
Lists and explains fault codes and types for slave devices.
Lists and explains fault codes and types for the display board.