PDM20 Series
-46-
Fault
code
Fault type Possible reasons Solution
3The power of the SPD is too
low
3Use bigger power SPD
E005
Over
voltage in
accelerated
running
1The input voltage is abnormal 1Check input power supply
2Restart rotating motor after
momentary outages
2Avoid restarting after it is stopped
E006
Over
voltage in
decelerated
running
1Too fast deceleration 1Increase acceleration time
2The inertia of load is too big 2Increase dynamic braking modules
3The input voltage is abnormal. 3Check input power
E007
Over
voltage in
constant
speed
running
1Abnormal changes happen to
input voltage
1Install input reactor
2The inertia of load is too big
2Add proper dynamic braking
modules
E008
Hardware
over
voltage
1The input voltage is abnormal 1Check input power supply
2Too fast deceleration 2Increase deceleration time
3The inertia of load is too big 3Increase dynamic braking modules
E009
Bus under
voltage
1The grid voltage is too low 1Check grid input power supply
E010
Controller
overload
1Too fast acceleration 1Increase acceleration time
2
Restart rotating motor 2Avoid restarting after it is stopped
3The grid voltage is too low 3Check grid voltage