code
Fault type Possible reasons Solution
4Overload 4Use bigger power SPD
E011
Motor
overload
1The grid voltage is too low 1Check grid voltage
2Wrong setting to motor rated
current
2Reset motor rated current
3Motor stall or big changes to
load
3Check the load and adjust torque
lifting capacity
4Motor is too small 4Use proper motor
E013
Output
phase loss
U,V,W phase loss output(or the
three phases of load is not
symmetrical)
1Check output wiring
2Check motor and cable
E014
Module
overheatin
g
1Instant over current of SPD 1Refer to over current solutions
2Output three phases have
interphase or ground is short
circuit
2Re-wiring
3Air passage block or fan
broken
3Dredge air passage or change fan
4The environmental
temperature is too high
4Decrease environmental
temperature
5SPD wire or plugins loose 5Check and re-connect
6Power circuit irregularity 6Seek for service