PDS33 Series
- 36 -
Function
Code
Function
Description
Unit
Factory
setting
Modification
Type
Communicati
on Address
FD.24
MPPT flag
/
/
0
◎
FD18
FD.25
MPPT
voltage added
0.0V~1.0V
0.1V
0
○
FD19
FE Group:Parameters management
FE.00
User password
0 ~ 65535
1
0
○
FE00
FE.01
Fault
record display
times
0 ~ 15
1
5
○
FE01
E0 Group:Current fault record
E0.00
Type of
current fault
record
0:No error
1:Reserved
2:Over current during
acceleration(Err02)
3:Over current during
deceleration(Err03)
4:Over current at
constant speed(Err04)
5:Over voltage during
acceleration(Err05)
6:Over voltage during
deceleration(Err06)
7:Over voltage at
constant speed(Err07)
8:Overload of buffer
resistor(Err08)
9:Under voltage error
(Err09)
10:Controller overload
(Err10)
11:Motor overload
(Err11)
12:Input phase loss
(Err12)
13:Output phase loss
(Err13)
14:Module overheat
(Err14)
15:External error
(Err15)
-
-
◎
E000