VM600
- 14 -
Parameter
Name
Setting Range
Default
Property
Address
F0.13
Retentive of digital setting
frequency
0:No retentive
1:retentive
1
●
000D
F0.14
Fan operating mode
0:Run when motor is running
1:Keep run when power on
0
○
000E
F0.15
AI1 Input Option
0:0-10V
1:4-20mA
2: 0-20mA
3:0-5V
4:0.5-4.5V
0
○
000F
F1.00
Default Setting Restoring
0:No Operation
1:Restore to factory default setting (not
including F2 parameters)
2:Clear error records
0
●
0100
F1.01
Parameters Lockup
0:Invalid
1:Valid
0
○
0101
F1.02
User Password
0~65000
0
○
0102
F2.00
Motor Rated Power
0.1kW~2.2kW
Determined
by Drive
Model
●
0200
F2.01
Motor Rated Voltage
0-380V
Determined
by Drive
Model
●
0201
F2.02
Motor Rated Frequency
0- F0.05
Determined
by Drive
Model 定
●
0202
F2.03
Motor Rated Current
1.00-10.00
Determined
by Drive
Model
●
0203
F2.05
Type of Motor
0:Single Phase
1:Three Phase
0
●
0205
F2.06
Single-phase motor main
and auxiliary winding turns
ratio
10 ~ 200
80
○
0206
F2.07
Single-phase motor current
correction factor
50 ~ 200
130
○
0207
F3.00
V/F Curve Setting
0:Linear
1:Multi-Point
0
●
0300
F3.01
Multi-Point Frequency 1
0.00Hz~F3.03
3
●
0301
F3.02
Multi-Point Voltage 1
0.0%~100.0%
8
●
0302
F3.03
Multi-Point Frequency 2
F3.03~F3.05
5
●
0303
F3.04
Multi-Point Voltage 2
0.0%~100.0%
15
●