04
2.2 Technical Speci󽗉cations
Model
Rated Power
(KW)
Rated Output
Current (A)
Adaptable Motor
kW HP
One phase power supply: 220V, 50Hz/60Hz
780-0D75-1 0.75 4 0.75 1
780-1D5-1 1.5 7 1.5 2
780-2D2-1 2.2 9.6 2.2 3
Three phase power supply: 380V, 50Hz/60Hz
780-0D75-4 0.75 2.1 0.75 1
780-1D5-4 1.5 3.8 1.5 2
780-2D2-4 2.2 5.1 2.2 3
780-4D0G-4 4 9 4 5.5
780-5D5G-4 5.5 13 5.5 7.5
2.3 Installation Environment Requirements
Ingress Protection Grade 󾗕 IP20
Installation Height 󾗕 The maximum is 1000 m (3280 ft) at sea level. If the
installation height is above this value, the current should be reduced by 1.2% for
every 10 m (328 ft) increase in height.
Ambient temperature at running 󾗕 0~40℃ (32~104 ℉)
Temperature at storage 󾗕 -20~55℃ (-4~131 ℉)
Temperature at tranportation 󾗕 -20~60℃ (-4~140 ℉)
Air Humidity
At running 󾗕 5%~85%, no condensation or freezing
At storage 󾗕 5%~95%