18
10.FAULTS, CAUSES AND REMEDIES
Only have faults remedied by qualified personnel! Follow the
safety instructions in Maintenance Maintenance.
If the operating fault cannot be remedied, please consult a
specialist technician or the nearest Salmson-sales service
point or representative.
11.SPARE PARTS
Spare parts are ordered via Salmson's after-sales service.
To avoid queries and incorrect orders, all data on the name
plate should be submitted with each order.
Subject to change without prior notice!
Fault Cause Remedies
LED lights up red
Electronic excess current release was trig-
gered
Check the pump and DIP switch settings.
After remedying the error, reset the LED dis-
play with the Reset button (Fig. 1b item 4).
LED flashes red
Pump current of 300 mA fallen short of or
phase L2 is missing
Check power supply, check pump and
pump cable.
After remedying the error, reset the LED dis-
play with the Reset button (Fig. 1b item 4).
LED lights up red
WSK was triggered or bridge on WSK terminals
is missing.
Check pump and wiring.
LED lights up red
High water alarm signal Check system/pump
All LEDs flash in sequence in an anti-
clockwise direction (running lights)
Incorrect phase sequence See direction of rotation check under 8 Com-
missioning