AFTER INSTALLATION
After completing installation and powering up the RT300 for the first time the
thermostat will behave in the following way:
All the indicators on the display and the backlight will be turned
on for two seconds. After two seconds, the RT300 will then
operate in Normal mode (Normal mode is when the thermostat
is displaying the room temperature).
The following table shows the settings of the RT300 digital thermostat
after Power on:
Function Status After Reset or Power On
Operation Mode Normal mode
Room Temperature 22.0 °C, updated within 5 seconds
Set Point Temperature 20.0 °C
°C indicator On
Frost Protection indicator Off
Heat indicator Off
Low-Battery Warning indicator Off, updated within 5 seconds
Output Relay Off
After Power on, the thermostat will operate in Normal mode (Normal mode is when
the thermostat is displaying the room temperature):
•
The set point temperature is reset to the default setting
•
The room temperature display is updated within 5 seconds
•
The control process starts
RT300 INSTRUCTION MANUAL
7