EasyManuals Logo

Salus RT500BC User Manual

Salus RT500BC
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
Once in Temporary Override mode, the
clock and day are displayed, along with the
SET indicator; all other indicators are cleared
from the display. The set point temperature
will flash to indicate that it can be changed:
The set point temperature can be adjusted
within 5 °C to 35 °C.
Temporary Override mode remains active until the new set point settings
are adjusted, Frost Protection is activated or the next programme time /
temperature set point is reached.
On/Off Control
When the RT500 is operating in NORMAL mode, if the Boiler Control has not
received a signal from the RT500 after 1 hour, the Boiler Control will turn off
the boiler, and the LED indicator will flash constantly (two times every
second).
Once the Boiler Control receives a valid ON or OFF signal, the Boiler Control
will control the heating system accordingly.
RT500BC INSTRUCTION MANUAL
22
Salus RT500BC Boiler Control 026_89 21/01/2012 18:18 Page 22

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Salus RT500BC and is the answer not in the manual?

Salus RT500BC Specifications

General IconGeneral
BrandSalus
ModelRT500BC
CategoryThermostat
LanguageEnglish

Related product manuals