12 • SPS-300 Series Program Information SPS-300 SmartECR Supplement v1.11
Flash ROM Update by SD
1. Create a folder named update in the root of the SD card.
2. Copy SPS300.bin to: SD:\update\SPS300.BIN.
3. Insert the SD card into the register. (The SD port is located inside the printer compartment.
Remove the security screw and open the flap securing the SD port. Insert the SD card until you
hear a click and the SD card is locked in.)
Boot Area Update
4. At the SPS-300, turn the control lock to the S position.
5. Power OFF the SPS-300.
6. Press and hold the Numeral 1 key on the keyboard. While continuing to hold the Numeral 1 key,
turn ON the power switch.
7. A rapid beep-beep-beep will be heard. Release the Numeral 1 Key.
8. The display the display will flash slowly at first and then will flash rapidly. When the load is
complete (about 5 seconds), a rapid beep-beep-beep will be heard again the display will stop
flashing and display a green color to confirm update completion.
9. Turn the ECR power switch OFF and proceed directly to the next step: Application Update.
Application Area Update
10. Set the control lock to the S position.
11. Press and hold the Numeral 2 key on the keyboard. While continuing to hold the Numeral 2 key,
turn on the power switch.
12. A rapid beep-beep-beep will be heard. Release the Numeral 2 Key.
13. The display will flash (Current program is being erased), after a few seconds, the display will
continue to flash, but at a slower rate. This continues for about 1-minute while the new program
is being loaded. When the load is complete, a rapid beep-beep-beep will be heard again the
display will stop flashing and display a green color to confirm update completion.
14. Power the register OFF. The application portion of the update is now complete.
15. Perform a Memory All Clear on the ECR. To complete the update procedure.