Translation of original instructions
EB 8048-2 EN
53-07
Type3349 Valve with Type3277 Pneumatic
Actuator and Type3730 Positioner
Type3349 Valve combined with Type3379
Pneumatic Piston Actuator and Type3724
Positioner
Edition June 2022
Type3349 Aseptic Angle Valve with USP-VI diaphragm
In combination with an actuator, e.g. a SAMSON Type3271 or
Type3277 Pneumatic Actuator or Type3379 Pneumatic Actuator

Table of Contents

Other manuals for Samson 3277

Questions and Answers

  • D
    donna35Sep 8, 2025
    What to do if the actuator and plug stem of my Samson Control Unit does not move?
    • Z
      zjohnsonSep 8, 2025
      If the actuator and plug stem do not move on demand, it could be due to the following reasons: * The actuator is blocked. Check the attachment and remove any blockage. Be careful, a blocked actuator or plug stem can suddenly start to move uncontrollably. Disconnect and lock the pneumatic air supply and control signal before unblocking. Release any stored energy in the actuator before unblocking. * The diaphragm in the actuator is defective. Please, refer to the associated actuator documentation for guidance. * The signal pressure is too low. Check the signal pressure and the signal pressure line for any leakage.
  • D
    Debra HamiltonSep 10, 2025
    Why doesn't the actuator and plug stem stroke through the entire range on my Samson Control Unit?
    • P
      Paul PhillipsSep 10, 2025
      If the actuator and plug stem do not stroke through the entire range, consider these potential causes: * The signal pressure may be too low. Inspect the signal pressure and check the signal pressure line for leaks. * The plug may have become detached. Fasten the plug and plug stem together. * The valve accessories might be set incorrectly. Verify the settings of the valve accessories.
  • J
    Joshua HowardSep 12, 2025
    What to do if there is increased flow through a closed Samson Control Unit valve?
    • B
      Beverly SellersSep 12, 2025
      If you observe increased flow through a closed valve (seat leakage), the following could be the cause: * Dirt or other foreign particles may be deposited between the seat and plug. Shut off the pipeline section and flush the valve. * The valve trim, particularly with a soft seat, may be worn. Replace the plug or contact after-sales service.
  • D
    davisdavidSep 13, 2025
    How to fix jolting movement of the actuator and plug stem in my Samson Control Unit?
    • R
      Robert DawsonSep 13, 2025
      If you're experiencing jolting movement of the actuator and plug stem, and you have a version with adjustable packing, the packing might be tightened too far. To resolve this, tighten the packing correctly. Refer to the 'Adjusting the packing' information in the 'Installation' section under 'Testing the installed valve'.
  • M
    macostaSep 15, 2025
    Why won't the actuator stem move on demand in my Samson Controller?
    • G
      gregory19Sep 15, 2025
      The actuator stem might not move on demand due to several reasons. It could be blocked; in this case, check the attachment and remove any blockage. Another cause might be insufficient signal pressure, so check the signal pressure and the signal pressure line for leakage.
  • D
    Danny WrightSep 18, 2025
    What to do if the actuator stem doesn't stroke through its complete travel range on a Samson 3277?
    • M
      martinezrebeccaSep 18, 2025
      If the actuator stem does not stroke through its complete travel range, it could be due to insufficient signal pressure. Therefore, check the signal pressure and the signal pressure line for leakage. Another possible cause is incorrect setting of valve accessories, so check the actuator without valve accessories and then check the settings of the valve accessories.

Summary

Safety Instructions and Measures

Notes on Possible Severe Personal Injury

Details severe personal injury risks from pressure equipment and bursting.

Notes on Possible Personal Injury

Covers burn risks from hot/cold components, noise, and exhaust air.

Markings on the Device

Design and Principle of Operation

Fail-Safe Action

Explains valve behavior upon signal pressure or air supply failure.

Shipment and On-site Transport

Transporting and Lifting the Valve

Safety precautions and methods for transporting and lifting the valve.

Installation

Installation Conditions

Covers work position and pipeline routing requirements for proper function.

Mounting the Device

Details the necessary activities for installing the valve and actuator.

Testing the Installed Valve

Outlines tests like leak test, travel motion, fail-safe position, and pressure test.

Start-up

Malfunctions

Troubleshooting

Provides a table of malfunctions, possible reasons, and recommended actions.

Emergency Action

Outlines plant operator responsibilities for emergency actions during valve malfunction.

Servicing

Checking the Extent of Servicing

Details checks for wear at seat, plug, and diaphragm, and torque checks.

Service Work for Version with Type 3271 or Type 3277 Actuator

Procedures for replacing packing and diaphragm/plug for specific actuator types.

Service Work for Version with Type 3379 Actuator

Procedures for servicing valves with the Type 3379 actuator.

Decommissioning

Removal

Repairs

Returning Devices to SAMSON

Detailed process for returning defective devices to SAMSON for repair.