General Specification
MIXER PART
NORMAL LIMIT
*MAXIMUM VOLTAGE GAIN
;MIC IN TO MONITOR L/R 62±3dBm
;MIC IN TO MONITOR L/R(MIC/LINE WITHIN) 32±3dBm
;MIC IN TO AMP OUT (MIC/LINE WITHIN,LIMITER LED JUST LIGHT) 58
±3dBm
;MONO LINE IN TO MONITOR L/R 20
±3dBm
;ST LINE IN TO MONITOR L/R 28
±3dBm
;MONO MIC IN TO REC OUT 38
±3dBm
*FREQUENCY RESPONSE (20HZ~20KHZ)
(LEVER VR NORMAL, MONITOR VR NORMAL OUTPUT LEVEL +4dBm)
;MIC IN TO MONITOR L/R
±2dB
;LINE IN TO MONITOR L/R
±2dB
;LINE IN TO REC L/R
±2dB
*MAXIMUM OUTPUT LEVEL
(OUTPUT LOAD 10K ohm,Before just clipping)
;MIC IN TO MONITOR L/R 21 dBm more than 20dBm
*T.H.D
( LEVEL , MONITOR VR NOMINAL, OUTPUT +14dBm, OUTPUT LOAD 10K ohm 80KHz LPF)
;MIC IN TO MONITOR L/R LESS than 0.1%
;LINE IN TO MONITOR L/R LESS than 0.1%
*HPF
(SPEECH/MUSIC ON 75Hz MONITOR OUTPUT) -3dB±1
*TONE CONTROL
(CH LEVEL ,MONITOR VR NORMINAL,OUTPUT +4dBm)
;10KHZ
±12dB ±12±3dB
;100HZ
±12dB ±12±3Db