11
English
Installation Procedure
Optional: Fixing the outdoor unit to a wall with
a rack
Soft rubber designed to cut off vibration from
rack to wall. (not supplied with product)
Designed to cut off residual vibration from
outdoor unit to rack. (not supplied with product)
Anchor bolt
Base surface
20 mm
Install a proper grommet in order to reduce noise
and residual vibration transferred by the outdoor unit
towards the wall.
CAUTION
When installing an air guide duct, be sure to check the
following:
The screws do not damage the copper pipe.
The air guide duct is fixed firmly on the guard fan.
Step 4 Connecting the power cables,
communication cable, and controllers
You must connect the following three electrical cables to the
outdoor unit:
The main power cable between the auxiliary circuit
breaker and the outdoor unit.
The outdoor-to-indoor power cable between the
outdoor unit and the indoor unit.
The communication cable between the outdoor unit
and the indoor unit.
CAUTION
During installation, make first the refrigerant
connections and then the electrical connections. If the
unit is uninstalled, first disconnect the electrical cables
and then the refrigerant connections.
Connect the air conditioner to the earthing system
before making the electrical connections.
NOTE
Especially, if your outdoor unit is the one designed for
Russian and European markets, consult the supply
authority, if necessary, to estimate and reduce the
supply system impedance before installation.
Air conditioning system examples
When using earth leakage circuit breaker (ELCB) for a single
phase
MCCB
1
ELB
Main power
cable
Communication cable
Outdoor-to-indoor power cable
Earthing
Outdoor Unit
OR
Indoor Unit
ELCB
1
When using earth leakage circuit breaker (ELCB) for a 3-phase,
4-wire system (3P4W)
MCCB
3 Ø
ELCB
3 Ø
ELB
Outdoor Unit Indoor Unit
Main power
cable
Communication cable
Outdoor-to-indoor power cable
Earthing
CAUTION
If the outdoor unit is installed in a location vulnerable
to an electric leak or submergence, make sure to install
an ELCB.
For the product that uses the R-32 refrigerant, be
cautious not to generate any sparks near the product by
keeping the following requirements:
Do not remove the fuses with power on.
Do not disconnect the power plug from the wall
outlet with power on.
It is recommended to locate the outlet in a high
position. Place the cords so that they are not
tangled.