31
English
Installation Procedure
7 Setting outdoor unit option switch and address manually
a Setting the option
• Press and hold K2 to enter the option setting.
(Only available when the operation is stopped)
– If you enter the option setting, display will show
the following.
– Seg 1 and Seg 2 will display the number for
selected option.
– Seg 3 and Seg 4 will display the number for set
value of the selected option.
• If you have entered option setting, you can shortly
press the K1 switch to adjust the value of the Seg 1,
Seg 2 and select the desired option.
Example)
• If you have selected desired option, you can shortly
press the K2 switch to adjust the value of the Seg 3,
Seg 4 and change the function for the selected option.
Example)
• After selecting the function for options, press and
hold the K2 switch for 2 seconds. Edited value of
the option will be saved when entire segments
blinks and tracking mode begins.
Option
item
Input
unit
SEG1 SEG2 SEG3 SEG4 Function
Channel
address
Main 0 0
AU
Automatic setting
(Factory default)
00~15 Manual setting
Snow
accumulation
prevention
control
Main 0 1
00
Disabled
(Factory default)
0 1 Enabled
Step for
Silence
mode
Main 0 2
00
Disabled
(Factory default)
01 Step1
02 Step2
03 Step3
Type of
Silence
mode
Main 0 3
00
Automatic
Silence mode
(Factory default)
01
Manual Silence
mode
Temperature
unit
Main 0 4
00
Celsius
(default)
0 1 Fahrenheit
Not
applicable
Main 0 5
0 0 Not applicable
0 1 Not applicable
Current
restriction
rate
ࠋࣕ
Main 0 6
00
100% (Factory
default)
01 95%
02 90%
03 85%
04 80%
05 75%
06 70%
07 65%
08 60%
09 55%
10 50%
1 1 100%
Display contents SEG1 SEG2 SEG3 SEG4
K4 long
push
- Main micom version Year (Dec) Month (Hex) Date (Tens digit) Date (Units digit)
After short push 1 Inverter micom version Year (Dec) Month (Hex) Date (Tens digit) Date (Units digit)
After short push 2 E2P version Year (Dec) Month (Hex) Date (Tens digit) Date (Units digit)
After short push 3
Page 1 - AUTO
Page 2 - (SEG1,2 - Indoor : "A","0") (SEG3,4 - Address : ex) 00)
After short push 4
Page 1 - MANU
Page 2 - (SEG1,2 - Indoor : "A","0") (SEG3,4 - Address : ex) 00)