29English
Appendix
Appendix
COMMISSION DELEGATED REGULATION (EU) No 626/2011
i)
PRODUCT FICHE (ENERGY LABELLING OF AIR CONDITIONERS)
ii)
A Supplier's name - Samsung Electronics Co.. Ltd.
B
Model name (Indoor/Outdoor)
-
AC026MN1DKH /
AC026MXADKH
AC026MNNDKH /
AC026MXADKH
AC026NNNDKH /
AC026MXADKH
AC026MNLDKH /
AC026MXADKH
C
Sound Power Level (Inside/Outside) dB(A)
52 / 59 48 / 59 48 / 59 53 / 59
D
Refrigerant name
1)
-
R-410A R-410A R-410A R-410A
E
GWP -
2088 2088 2088 2088
F
SEER
6,2 6,9 6,9 6,1
G
Energy efciency class (SEER) -
A++ A++ A++ A++
H
Q
CE
2)
(cooling season) kWh/a
iii)
147 132 132 149
I
Pdesignc kW
2,6 2,6 2,6 2,6
J
SCOP (Average) -
4,0 4,3 4,3 4,0
K
Energy efciency class SCOP (Average) -
A+ A+ A+ A+
L
Q
HE
3)
heating season (Average) kWh/a
iii)
700 684 684 700
M
Pdesignh (Average) kW
2,0 2,1 2,1 2,0
N
Back up heating capacity (Average) kW
0 0 0 0
O
Declared capacity(Average) kW
2,0 2,1 2,1 2,0
P
Other heating seasons suitable for use -
-
iv)
Q
SCOP (Warmer) -
- - - -
R
Energy efciency class SCOP (Warmer) -
- - - -
S
Q
HE
3)
heating season (Warmer) kWh/a
iii)
- - - -
T
Pdesignh (Warmer) kW
- - - -
U
Back up heatingcapacity (Warmer) kW
- - - -
V
Declared capacity (Warmer) kW
- - - -
W
SCOP (Colder) -
- - - -
X
Energy efciency class SCOP (Colder) -
- - - -
Y
Q
HE
3)
heating season (Colder) kWh/a
iii)
- - - -
Z
Pdesignh (Colder) kW
- - - -
AA
Back up heating capacity (Colder) kW
- - - -
AB
Declared capacity (Colder) kW
- - - -
1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would
contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere.
This appliance
contains a refrigerant fluid with a GWP equal to [2088].
This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global
warming would be [2088] times higher than 1 kg of CO
, over a period of 100 years.
Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always
ask a professional.
2 Energy consumption “XYZ” kWh per year, based on standard test results.
Actual energy consumption will depend
on how the appliance is used and where it is located.
3 Energy consumption “XYZ” kWh per year, based on standard test results. Actual energy consumption will depend
on how the appliance is used and where it is located.
Appendix