03 OTHERS
35
English
Packing and unpacking guide
Outdoor unit
f Packing the unit as below procedure
1. Fix the outdoor unit and the wood palette by 4 screws.
2. Put the cushion-top onto the outdoor unit.
3. Put the packing case from the top of set.
4. Seal the packing case.
f Unpacking the unit as below procedure
1. Take out the packing case from the set.
2. Take out the cushion-top.
3. Unscrew 4 screws from the wood palette and then move the set.
MODEL AC012MXQFEC AC018MXQFEC AX024MXQFEC
CLIMATES CLASS T1 T3 T1 T3 T1 T3
RATED CAPACITY
COOLING
12000 Btu/h 10200 Btu/h 18000 Btu/h 15300 Btu/h 21000 Btu/h 18700 Btu/h
3.52 kW 2.99 kW 5.28 kW 4.48 kW 6.15 kW 5.48 kW
HEATING
---
RATED VOLTAGE & FREQUENCY
220 - 240 V ~ 50 Hz 220 - 240 V ~ 50 Hz 220 - 240 V ~ 50 Hz
RATED CURRENT
COOLING 4.7A 5.6A
6.9A 8.2A 8.0A 10.0A
HEATING
---
RATED POWER
INPUT
COOLING 1.0 kW 1.2 kW
1.5 kW 1.8 kW 1.75 kW 2.2 kW
HEATING
---
EER/COP
COOLING
12.0(Btu/h)/W
8.5(Btu/h)/W
12.0(Btu/h)/W 8.5(Btu/h)/W 12.0(Btu/h)/W 8.5(Btu/h)/W
HEATING
---
POWER FACTOR
COOLING 0.92 0.94 0.95 0.96 0.95 0.97
HEATING -
--
MAX CURRENT
11.5A 20.5 A 20.5 A
DESIGN PRESSURE
H:4.1 Mpa, L:1.4 Mpa H:4.1 Mpa, L:1.4 Mpa H:4.1 Mpa, L:1.4 Mpa
ANNUAL ENERGY
CONSUMPTION
for 2,000Hr - -----
for 2,700Hr 2700 kWh 3240 kWh 4050 kWh 4860 kWh 4725 kWh 5940 kWh
REFRIGERANT R-410A 0.8kg R-410A 0.9kg R-410A 1.1kg
IP NUMBER IPX4 IPX4 IPX4
NET WEIGHT 29.0 kg 37.0 kg 46.5 kg
DIMENSIONS OF THE UNIT
[W×H×D]
790*548*285 880*638*310 880*798*310
COUNTRY OF ORIGIN MADE IN KOREA MADE IN KOREA MADE IN KOREA
Product specication