EasyManuals Logo

Samsung AC018JN4DCH/AA User Manual

Samsung AC018JN4DCH/AA
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
Troubleshooting
Samsung Electronics 4-27
Outdoor inverter PBA
checking part
Indoor control PBA checking part
8IFOUIFPVUEPPSVOJUQPXFSJTOPU0/o*OJUJBM%JBHOPTJT4JOHMFQIBTFQSPEVDU
(Continued)
Yes
After replacing the main PBA and resetting
the power, check everything is normal.
Connect the power supply.
(Switch off power to the terminal box!)
1. Connect the power supply.
2. Check whether the power of the outdoor unit
is supplied by powering on the terminal box.
No
No
Check the power parts.
(Switch off power to
the terminal box before inspection!)
1. Is there a fault with a fuse??
(Short-Normal, Open-Fault)
2. When the bridge diode is measured with +, -
(output voltage), does the voltage exceed
290 Vdc?
3. Is the power supply voltage 12V?
4. Is there a fault with a fuse of EMI PBA?
(Short-Normal,
Open-Fault)
Fan Motor Connector
After separating and resetting
the power, check everything is normal.
(Separate the connector after turning off the
power to the terminal box!
When detaching and attaching the connector
during power supply, the motor can be
damaged.) ױ If it is normal,
replace the fan motor.
Fan Motor
Connector
Continued
Outdoor main PBA checking part
Outdoor EMI PBA checking part
Fuse
12V power
Fuse
Bridge Diode
EMI PBA Fuse
[RC090/100/125/140/1456HXE6,
RC100DHXB6]
Indoor control PBA checking part
Display PBA checking part
Bridge Diode (back)
Front Fuse
[RC072DHXB6]
12V power
[RC072DHXB6]