Troubleshooting
4-18 Samsung Electronics
4-3-11 E462 : Current protection control causes comp. down
E484 : PFC overload error
No
No
Yes
Finished inspections
Outdoor unit display E462,E484
Criteria
t5IFPVUEPPSNBDIJOFJOQVUDVSSFOUBCPWF*@5SJQ
Cause of problem
t$IFDLUIFDPNQSFTTPSJOQVUWPMUBHFFSSPSGPSMPXWPMUBHF
t$IFDLUIFPWFSDVSSFOUPQUJPOTFUUJOH
1. How to check
Overcurrent option setting ok?
Compressor input voltage supplied ok?
Check the input power terminal.
Correct the overcurrent setting.