2-3 Refrigerating Cycle Block Diagram
Refrigerating cycle temperature and pressure
STD Pressure Piping Temp.(°C) Temp. Condition (°C)
Operating Condition (kg/cm
2
G)
T1 T2
Indoor Outdoor
3-way valve DB WB DB WB
Standard 5.0~5.2 11 11 27 19 35 24
A or B Max over load 6.0~6.3 16 15 32 23 43 26
Cooling Low temp. 3.4~3.6 3 2 21 15 21 15
Standard 5.0~5.2 12 10 27 19 35 24
A + B Max over load 6.0~6.3 16 15 32 23 43 26
Low temp. 3.4~3.6 3 2 21 15 21 15
INDOOR UNIT
T1
T2 Gas side
Cooling
Compressor-A
Gas leak
check point
Liquid side
Capillary tube
2-way valve
3-way valve
Heat
exchanger
(Evaporator)
Heat
exchanger
(Condenser)
(A) (B)