Samsung Electronics 156
Troubleshooting
4-4-12 Case study – E461/361 & E464/364 & E466/366
ƒ Check whether compressor defect or Inverter PBA defect.
E461/464 / 466
E361/364 / 366
ƒ Diagnosis 1 : Using inverter checker
1. Power Off
2. Wait more than 15 minutes after the Power Off as in case of IPM failure,
discharge mode may not work properly.
3. Connect inverter checker(Phase checker)(U : RED / V : WHT / W : BLK)
4. Execute inverter checker function in OUD main PBA.
5. If any LED is not blinking ĺ PBA defect ĺ Change PBA
OK NG
Check with
Inverter checker
2
nd
visit
Comp replace
Order comp
1
st
visit 3
rd
visit Completion
Inverter PBA
order
2
nd
visit
PBA replace
4
th
visit
Comp replace
Comp order