EasyManua.ls Logo

Samsung AM280FNHDEH - Wiring Work

Samsung AM280FNHDEH
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
1
Before wiring work, you must turn off all power source.
2
Indoor unit power should be supplied through the breaker
( ELCB or MCCB+ELB ) separated by the outdoor power.
ELCB: Earth Leakage Circuit Breaker
MCCB: Molded Case Circuit Breaker
ELB: Earth Leakage Breaker
3
The power cable should be used only copper wires.
4
Connect the power cable{1(L), 2(N)} among the units within maximum
length and communication cable(F1, F2) each.
5
Connect F3, F4(for communication) when installing the wired remote
control.
Power and communication cable connection
Wiring Work
Connecting power for optional product
When installing optional product, make sure to follow below current capacity.
Optional product is not supplied by manufacturer.
AC, Below 2A AC, Below 2A
HOT
T/B
1(L) 2(N) Vc Vc Vw Vw
POWER : L
VENTILATOR
OPTION
POWER : N
COIL
ELCB
MCCB+
ELB
Indoor Unit 1
Outdoor Unit
Indoor Unit 2 Indoor Unit 3
Wired Remote
Control
220-240V~
or
ELCB : Essential Installation
WARNING :
Power off before connecting any wires;
Indoor PBA will be damaged while V1,V2,F3,F4 short each other.
NASA_Big Duct_AM@@@FNHDEH@_IM_EN_03653A-06.indd 18 2016-12-01 오후 3:06:54

Other manuals for Samsung AM280FNHDEH

Related product manuals