EasyManua.ls Logo

Samsung AQV12JAX - Block Diagram; Indoor Unit

Samsung AQV12JAX
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Samsung Electronics
HEAT EXCHANGER SENSOR
INDOOR FAN MOTOR
BUZZER
COMPRESSOR
OUTDOOR FAN MOTOR
4-WAY VALVE
STEPPING MOTOR
: BLADE CONTROL
IC-MCU
ROOM TEMPERATURE SENSOR
CONTROLLER
REMOTE CONTROL
TEMPERATURE
OPERATION
AUTO CLEAN
TURBO
ENERGY SAVING
TIMER
ANION
FAN SPEED
DISPLAY PART
ANION
INFRARED SIGNAL
OSCILLATION
CIRCUIT
POWER ON/OFF
TURBO OPERATION
ANION SELECT
AUTO CLEAN SELECT
SLEEP OPERATION
MODE
(AUTO, COOL, DRY, FAN,
HEAT)
FAN SPEED SELECT (H/M/L/
AUTO)
BLADE-H
MOVING SELECT
ON, OFF TIMER
SELECT/CANCEL
ENERGY SAVING SELECT
SOUND ON/OFF SELECT
DIGITAL
ON/OFF
TEMPERATURE
SELECT(UP/DOWN)
ZERO
VOLTAGE
DETECT
TRIGGER
SIGNAL
SSR
STEPPING MOTOR DRIVE
BUZZER DRIVE
ANION DRIVE*
COMPRESSOR CONTROL
SIGNAL
STEPPING MOTOR
CONTROL SIGNAL
BUZZER MELODY CONTROL
SIGNAL
ANION CONTROL SIGNAL*
DC5V
DC12V
AC INPUT
VOLTAGE REGULATOR
OPTION
MELODY CONTROL PART
SPEAKER
12. Block Diagram
12-1 Indoor Unit
BLADE CONTROL
INDOOR FAN MOTOR CONTROL
OUTDOOR COMMUNICATION
POWER RELAY CONTROL
TEMPERATURE CONTROL
TIMER
BUZZER MELODY CONTROL
ANION CONTROL
*: OPTION
12-1
COMMUNICATION
SIGNAL
OUTDOOR UNIT
DC5V
DC12V
AC230V
DC25V
SMPS POWER BLOCK