INSTALLING THE AIR CONDTIONER
When you install the unit, make first refrigerant connections and then elec-
trical connections. Connect the air conditioner to grounding system before
performing the electrical connection. If unit is uninstalled first disconnect
electrical cables, then refrigerant connections.
The outdoor unit is powered from the indoor unit through the assembly cable.
If the outdoor unit is more than 5 meters away from the indoor unit, you must
extend the cable. The maximum length of the cable is 15
(
09/12
)/100(
18/24
) meters.
1
Extend the assembly cable if necessary.
2
Open the front grille by pulling on the tabs on the lower right and left sides of
the indoor unit.
3
Remove the screw securing the connector cover.
4
Pass the assembly cable through the rear of the indoor unit and connect
the assembly cable to terminals as seen in the picture.
Each wire is labeled with the corresponding terminal number.
5
Pass the other end of the cable through the 65mm hole in the wall.
6
Close the connector cover, tightening the screw carefully.
7
Close the front grille.
8
Remove the terminal board cover on the side of the outdoor unit.
9
Connect the cables to the terminals as seen in the picture.
Each wire is labeled with the corresponding terminal number.
10
Connect the grounding conductor to the grounding terminals.
11
Close the terminal board cover, tightening the screw carefully.
12
Connect the power cable to the indoor unit.
In Russia and Europe, consult with the supply authority to determine
the supply system impedance before installation.
Connecting the Assembly Cable
Power cable specification
Connect the power cable to the auxiliary circuit breaker.
If every pole fails to connect to the power supply, it must be
incorporated in a wire with a contact opening of ≥3mm.
The designs and shape are subject to
change according to the model.