E-5
ENGLISH
Choosing the Installation Location
Avoid the following places to prevent malfunction of the unit
- Where there is machine oil - Salty environment such as the seaside areas
- Where sulfide gas exists - Other special atmosphere areas
CAUTION
Indoor Unit Outdoor Unit
Where airflow is not blocked
Where cool air can be distributed throughout the room
Install the refrigerant piping length and the height
difference of both indoor and outdoor units as
indicated in the installation diagram
Wall that prevents vibration and is strong enough to hold the
product weight
Out of the direct sunlight
1m or more away from the TV or radio
(to prevent the screen from being distorted or noise from being
generated)
As far away as possible from fluorescent and incandescent lights
(so that the remote control can be operated well)
A place where the air filter can be replaced easily
Where it is not exposed to strong wind
Well ventilated and dustless places
Out of the direct sunlight and rain
Where neighbors are not annoyed by operation sound or hot air
Solid wall or support that prevents vibration and is strong
enough to hold the product weight
Where there is no risk of flammable gas leakage
When installing the unit at a high place be sure to fix the unit
legs
3m or more away from the TV or radio (to prevent the screen
from being distorted or noise from being generated)
Install the unit horizontally
PREPARING FOR INSTALLATION
Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner.
125 mm
or more
300 mm or more
125 mm
or more
600 mm
minimum
300 mm
minimum
300 mm
minimum
600 mm
minimum
Wrap the refrigerant pipes and the drain
hose with the absorbent pad and vinyl
tape. Refer to page 18 for further details.
You can select the direction
of draining. (left or right)
The appearance of the unit may be different from the diagram depending on the model.
CAUTION:
'L' m as maximum pipe length and 3 m as
minimum pipe length (It will reduce noise
and vibration)
Make at least one round:
It will reduce noise and vibration
'L' meters maximum
total pipe length
'H' meters maximum
total pipe Height
Model L H

09/12

15
8

18/2
4

30 15