Alignment & Troubleshooting
Service Manual
4-17
Samsung Electronics
Code LCD display Meaning
Default
Min. / Max Description
109-0010 0010-Print
Temp
Target Temperature
during run mode.
0 -10 ~ 0 1. Description
: As (-) value increases, fusing temperature goes
down in normal mode.
2. Symptom
: Hot offset takes place, or printed paper is too hot.
Hot offset : When Fusing temperture is too
high, printed image appears again in 95mm
cycle
3. Solution
: Drop Fusing temperature by increasing (-) value.
109-0020 0020-Low
Power Temp
Target Temperature
during Power save
mode.
0 -10 ~ 0 Reserved
109-0070 0070-Bond
Temp
Media type offset
for fuser roller
temperature.
0 -10 ~ 0 1. Description
: As (-) value increases, fusing temperature goes
down in bond paper mode.
2. Symptom
: Hot offset takes place, or printed paper is too hot
when bond paper is printed.
Hot offset : When Fusing temperture is too
high, printed image appears again in 95mm
cycle
3. Solution
: Drop Fusing temperature by increasing (-) value.
109-0080 0080-Trans
Temp
Media type offset
for fuser roller
temperature.
0 -10 ~ 0 1. Description :
As (-) value increases, fusing temperature goes
down in OHP mode.
2. Symptom
: Hot offset takes place, or printed paper is too hot
when OHP is printed.
Hot offset : When Fusing temperture is too
high, printed image appears again in 95mm
cycle
3. Solution
: Drop Fusing temperature by increasing (-) value.