Code LCD display Meaning
Default
Min. / Max Description
109-0100 0100-
Envelopes
Temp
Media type offset
for fuser roller
temperature.
0 -10 ~ 0 1. Description
: As (-) value increases, fusing temperature goes
down in Envelope mode.
2. Symptom
: Hot offset takes place, or printed paper is too hot
when Envelope is printed.
※ Hot offset : When Fusing temperture is too
high, printed image appears again in 95mm
cycle
3. Solution
: Drop Fusing temperature by increasing (-) value.
109-0110 0110-Labels
Temp
Media type offset
for fuser roller
temperature.
0 -10 ~ 0 1. Description
: As (-) value increases, fusing temperature goes
down in label mode.
2. Symptom
: Hot offset takes place, or printed paper is too hot
when label is printed.
※ Hot offset : When Fusing temperture is too
high, printed image appears again in 95mm
cycle
3. Solution
: Drop Fusing temperature by increasing (-) value.
109-0120 0120-Fuser
Bias Duty
Fuser Bias Duty 0 -10 ~ +10 1. Description
: As the digit value increases, fuser bias increases.
2. Symptom
: When it is cold and dry, printed image of pastel
tone appeas again in 95mm cycle.
3. Solution
: Increase fuser bias by increasing the digit.