Operating advanced function _43
ENGLISH
Others : Code 50
Outing Mode (Hot Key of Wired Remote Controller)
• All the target temperatures (both water outlet and room) for space heating/cooling/
auto(water-law) modes and the target tank temperature for DHW heating mode will be
changed to the values defined in the table above to save energy consumption during the
vacancy of house.
Withtheloweredtargettemperatures(FSV#5011~#5019),thesystemwillbeoperated
normally.
Economic DHW Heating
• Which is heat pump only, saving energy consumption. A target temperature of DHW shall be
lowered as much as Users set with field setting values stored in wired remote controller.
 - New target DHW tank temperature will be the value subtracted the difference (#5021) from
the present user’s setting.
FieldSettingValue
Main Menu &
Code
Sub Menu Function Description
Sub
Code
Default Min Max Step Unit
Others Code
50
Outing Water Out Temp for
Cooling
11 25 5 25 1 ˚C
Room Temp for Cooling 12 30 18 30 1 ˚C
Water Out Temp for
Heating
13 25 15 55 1 ˚C
Room Temp for Heating 14 16 16 30 1 ˚C
Auto Cooling WL1 Temp 15 25 5 25 1 ˚C
Auto Cooling WL2 Temp 16 25 5 25 1
Auto Heating WL1 Temp 17 15 15 55 1 ˚C
Auto Heating WL2 Temp 18 15 15 55 1 ˚C
Target Tank Temp 19 30 30 70 1 ˚C
DHW Saving Mode Temp Difference 21 5 0 40 1 ˚C
Power Peak Control Application 41 0(No) 0 1(Yes) - -
Select forced off parts 42 0(All) 0(All) 3 1 -
Contact Logic 43 1(High) 0(Low) 1 - -