Operating advanced function _43
ENGLISH
Others : Code 50
Outing Mode (Hot Key of Wired Remote Controller)
• All the target temperatures (both water outlet and room) for space heating/cooling/
auto(water-law) modes and the target tank temperature for DHW heating mode will be
changed to the values defined in the table above to save energy consumption during the
vacancy of house.
Withtheloweredtargettemperatures(FSV#5011~#5019),thesystemwillbeoperated
normally.
Economic DHW Heating
• Which is heat pump only, saving energy consumption. A target temperature of DHW shall be
lowered as much as Users set with field setting values stored in wired remote controller.
- New target DHW tank temperature will be the value subtracted the difference (#5021) from
the present user’s setting.
FieldSettingValue
Main Menu &
Code
Sub Menu Function Description
Sub
Code
Default Min Max Step Unit
Others Code
50
Outing Water Out Temp for
Cooling
11 25 5 25 1 ˚C
Room Temp for Cooling 12 30 18 30 1 ˚C
Water Out Temp for
Heating
13 25 15 55 1 ˚C
Room Temp for Heating 14 16 16 30 1 ˚C
Auto Cooling WL1 Temp 15 25 5 25 1 ˚C
Auto Cooling WL2 Temp 16 25 5 25 1
Auto Heating WL1 Temp 17 15 15 55 1 ˚C
Auto Heating WL2 Temp 18 15 15 55 1 ˚C
Target Tank Temp 19 30 30 70 1 ˚C
DHW Saving Mode Temp Difference 21 5 0 40 1 ˚C
Power Peak Control Application 41 0(No) 0 1(Yes) - -
Select forced off parts 42 0(All) 0(All) 3 1 -
Contact Logic 43 1(High) 0(Low) 1 - -