4-23
Samsung Electronics
Installation
The following electrical characteristics must be respected.
MODEL
Power
Sub switch
Fuse
Min. size of electric Wires
from/to the indoor/outdoor unit
Size of electric input wires
20m or less
50m or less
ADH1800E/ADH2400E
DH18ZA1(A2)/DH24ZA1(A2)
1Ø, 220V-240V~, 50Hz
30A
30A
The power cables are not
supplied with the air conditioner.
The user should purchase them
separately.
H07RN-F, 4G, 1.0mm
2
H07RN-F, 3G, 2.5mm
2
H07RN-F, 3G, 4.0mm
2
H07RN-F, 4G, 1.0mm
2
H07RN-F, 3G, 4.0mm
2
H07RN-F, 3G, 6.0mm
2
ADH3200E
DH32ZA1(A2)
Note
Wiring Diagram
Cable Specifications
DIP Switch
CN20 Connector
CN7
SW2
CN9
Jumper
Wire
Receiver &
Display Unit
(Optional)
Float Switch
Drain Pump
Power
EARTH
Communication
Centralized
Controller
(Optional)
Float Switch
Drain Pump
(Optional)
Wired
Remote
Controller
(Optional)
Ventilator
Motor
Transmitter
(Optional)
Rotary
Digital
Switch
220-240V~, 50Hz
MAIN POWER
220-240V~, 50Hz
MAIN POWER
Outdoor Unit
Indoor Unit