Radiant Sensor(10RS)
Resistancevalue<1Ω
Ifresistanceisinnite,replaceRadiantsensor
Igniter(101D)
Resistancevalue40~400Ω
If resistance is innite, replace Igniter
Gas Valve(25M01A)
Valve1-2:Resistancevalueabout1.2KΩ
Valve1-3:Resistancevalueabout0.5KΩ
Valve4-5:Resistancevalueabout1.2KΩ
If resistance is innity, replace Valve
Thermostat (60T21 Hi-Limit)230F-50F
Resistancevalue<1Ω
If resistance is innity, replace Thermostat