This appliance must be installed by a qualified technician or installer.
Prior to installation, ensure that the local distribution conditions
(nature of the gas and gas pressure) and the adjustment of the
appliance are compatible.
The adjustment conditions for this appliance are stated on the label
(or data plate).
This appliance is not connected to a combustion products evacuation
device. It shall be installed and connected in accordance with current
installation regulations. Particular attention shall be given to the
relevant requirements regarding ventilaton.
Before installing, turn off the gas and electricity supply to the
appliance.
All appliances containing any electrical components must be earthed.
Ensure that the gas pipe and electrical cable are installed in such a
way that they do not touch any parts of the appliacne which become
hot.
Gas pipe or connector shouldn’t be bent or blocked by any other
appliances.
Check the dimensions of the appliance as well as the dimensions of
the gap to be cut in the kitchen unit.
The panels located above the work surface, directly next to the
appliance, must be made of non-flammable material. Both the strati
-
fied surfacing and the glue used to secure it should be heat resistant,
to prevent deterioration.
Turn on appliance tap and light each burners.
Check for a clear blue flame without yellow tipping.
If burners shows any abnormalties check the following :
- Burner lid on correctly
- Flame spreader positioned correctly
- Burner vertically aligned with injector nipple
A full operational test and a test for possible leakages must be carried
out by the fitter after installaion.
The flexible tube shall be fitted in such a way that it cannot come into
contact with a moveable part of the housing unit and does not pass
through any space susceptible of becoming congested.