Alignment & Adjustment
Samsung Electronics 3-5
3. CCA(OFF)
No Item Range Default Remark
1 CCA CONTROL ON/OFF ON CCA On/Off Selection
2 Sensor Status NG_G_ Sensor valure
3 Red-x 0~32768 703 Red-x measurement value using CA210
4 Red-y 0~32768 292 Red-y measurement value using CA210
5 Red-Y 0~32768 80.0 Red-Y measurement value using CA210
6 Green-x 0~32768 173 Green-x measurement value using CA210
7 Green-y 0~32768 731 Green-y measurement value using CA210
8 Green-Y 0~32768 300.0 Green-Y measurement value using CA210
9 Blue-x 0~32768 146 Blue-xmeasurement value using CA210
10 Blue-y 0~32768 31 Blue-y measurement value using CA210
11 Blue-Y 0~32768 25.0 Blue-Y measurement value using CA210
12 ColorSensorSave Color Sensor valure save
13 WB Spread
14 [COOL2]DW_X 264
15 [COOL2]DW_Y 267
16 [COOL1]DW_X 269
17 [COOL1]DW_Y 274
18 [NORMAL]DW_X 276
19 [NORMAL]DW_Y 282
20 [WARM1]DW_X 285
21 [WARM1]DW_Y 293
22 [WARM2]DW_X 300
23 [WARM2]DW_Y 310
24 MaxCurrent RED 0
25 MaxCurrent GRN 0
26 MaxCurrent BLU 0
27 Sens RED 2604
28 Sens GRN 2244
29 Sens BLU 3238