Connecting the Connection Cord
Wiring Diagram
Indoor Unit
Outdoor Unit
Cable H07 RN-F
CommunicationPower
Always remember to connect the refrigerant pipes before performing the electric connections.
When disconnecting the system,always disconnect the electric cables before disconnecting the
refrigerant pipes.
Always remember to connect the air conditioner to the grounding system before performing the
electric connections.
CC
CC
AA
AA
UU
UU
TT
TT
II
II
OO
OO
NN
NN
The indoor unit is powered by the outdoor unit by means of a H07 RN-F
connection cable (or a more power model), with insulation in synthetic
rubber and jacket in polychloroprene(neoprene), in accordance with the
requirements of standard EN 60335-2-40.
Remove the screw on the electrical component box and remove the cover
plate.
1
Route the connection cord through the side of the indoor unit and connect
the cable to terminals; refer to the figure below.
2
Route the other end of the cable to the outdoor unit through the ceiling &
the hole on the wall.
3
Reassemble the electrical component box cover, carefully tightening the
screw.
4
Power supply
Communication
220-240V~, 50Hz
-
1.0 mm
2
or more, 3 wires
1.0 mm
2
or more, 2 wires
1Km
1Km
Indoor-Outdoor units Power (±10%) Power cable Max. Length
Size of the cables used to interconnect the indoor and outdoor units.