EasyManua.ls Logo

Samsung MH FKEA Series - COMPLETING THE INSTALLATION; Troubleshooting

Samsung MH FKEA Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E-
26
C
OMPLETING THE INSTALLATION
Troubleshooting
Detection of errors
If an error occurs during the operation, an LED flickers and the operation is stopped except the LED.
If you re-operate the air conditioner, it operates normally at first, then detect an error again.
LED Display
LED Display on the indoor unit
Error of indoor unit:
Displayed on the indoor
unit regardless of operation
Power reset
Error of temperature sensor in indoor unit
(OPEN/SHORT)
Error of heat exchanger sensor in indoor unit
Error of heat exchanger OUT sensor in indoor unit
Error of outlet temperature sensor in indoor unit
(OPEN/SHORT): For heat pump models only
Error of mixed operation
Error of indoor fan motor:
Below 450RPM for 15 minutes
Error of outdoor temperature sensor
Error of COND sensor
Error of DISCHARGE sensor
1.
No communication for 2 minutes between
indoor unit and outdoor unit (communication
error for more than 2 minutes)
2. Indoor unit receiving the communication
error from outdoor unit
3. Outdoor unit tracking 3 minutes error
4. When sending the communication error
from outdoor unit due to the mismatching
of the communication numbers and
installed numbers after completion of
tracking (communication error for more
than 2 minutes)
XXX
XXX
XXXX
X
X
X
XXX
X
X
X
X
XX
X
X
On Flickering X Off
Operating
Indicators
Abnormal conditions
Green
MH✴✴✴FKEA
MH✴✴✴FSEA
MH✴✴✴FMEA
Red Yellow Green
Orange
MH***FKEA IM_E_27682_4 5/25/04 3:28 AM Page 26

Related product manuals