21Samsung Electronics
30
14090
410~730
■ MH026FPEA / MH035FPEA / MH052FPEA
Before fixing the installation plate to a wall or window frame, you must determine
the position of the 65 mm hole through which the cable, piping and hose pass to
connect the indoor unit up to the outdoor unit. When facing the air conditioner in
position on the wall, the piping and cable can be connected from the:
• Right
• Left
• Rear (right or left)
• Underside: ✳✳18✳✳
1. Determine the position of the pipe and drain hose hole using the right figure and
drill the hole with an inner diameter of 65 mm so that it slants slightly downwards.
2.
3. Fix the installation plate to the wall in a manner appropriate to the weight of the
indoor unit.
- If you are mounting the plate on a concrete wall with anchor bolts, the anchor
bolts must not project by more than 20 mm.
4. Determine the positions of the wooden uprights to be attached to the window frame.
5. Attach the wooden uprights to the window frame in a manner appropriate to the
weight of the indoor unit.
6. Using tapped screws, attach the installation plate to the wooden uprights,
as illustrated in the last figure right.
30mm
Installation plate
✴✴26 / 35✴✴
✴✴52✴✴
Pipe hole
(
Ø65mm)
(Unit : mm)
(Unit : mm)
45
415512
30mm
Installation plate
Pipe hole
(
Ø65mm)
(Unit : mm)
(Unit : mm)
3-4 Fixing the Unit
Then follow Steps...
3.
4 to 6.
If you are fixing the indoor unit to a...
Wall
Window frame
DB98_20402A(1)_1 10/26/04 2:48 PM Page 21