83Samsung Electronics
If the air conditioner is used at... Then...
High temperatures The automatic protection feature may be triggered and the air conditioner
stopped.
Low temperatures A water leakage or some other malfunction may happen if the heat exchanger
freezes.
High humidity levels Water may condense on and drip from the surface of the indoor unit
if it is used for long periods.
Mode Outdoor Temperature Indoor Temperature Indoor Humidity
Heating -15°C to 24°C approx. 27°C or less -
Cooling -5°C to 43°C approx 21°C to 32°C approx. 80% or less
Drying -5°C to 43°C approx. 21°C to 32°C approx. -
❇ The standardized temperature for heating is 7°C. If the outdoor temperature drops to 0°C or below, the heating capacity can
be reduced depending on the temperature condition.
❇ If the cooling operation is used at over 32°C(indoor temperature) then, it does not cool at its full capacity.
6-3 Temperature and Humidity Ranges
The following table indicates the temperature and humidity ranges within which the air conditioner can be used.
DB98_20402A(1)_1 10/26/04 3:02 PM Page 83