69Samsung Electronics
No Parts Procedure Remark
1 Common Work
&
Control Out
1) Loosen the fixing screw and detach the
Cover-Valve.
2) Detach the Cable-Connector Wire from
the Terminal-Block.
3) Loosen 5 fixing screws and detach the
Cabinet-Upper.
4) Loosen 5 fixing screws from the
Ass'y-Control Out.
5) Detach the Terminal-Housing from the
Ass'y-Control Out.
6) Detach the Ass'y-Control Out from the
outdoor unit.
7) Loosen 7 fixing screws and detach
the Cabinet-Side.
4-2-1 MH068FXEA4 / MH080FXEA4
4-2 Outdoor Unit
Take care of the electrical shock by contact on the charging parts before the discharge after power off. (If takes approximately
2 minutes to discharge.)
DB98_20402A(1)_1 10/26/04 2:55 PM Page 69