Feature & Operation
75Samsung Electronics
6-1-4 Sleeping Operation
●
AT COOLING MODE
When you set the sleep mode, the following movement will start to avoid over cooling.
◆ The indoor fan speed is fixed by setting the remote control.
◆ The setting temperature will rise by 1°C at the starting of operation and by 1°C one hour later.
◆ The operation will stop after 6 hours.
●
AT HEATING MODE
When you set the sleep mode, the following movement will start to avoid overheating.
◆ The indoor fan speed is fixed by setting the remote control.
◆ The setting temperature will be dropped by 1°C at the starting of operation and by 1°C one hour later.
◆ The operation will stop after 6 hours
.
Start
Stop
1°C up
1°C up
1h
Ts
Ts+1
Ts+2
6h
Start
Stop
6hr
1°C down
1°C down
Ts+2
Ts+1
Ts+3
Ts+4
Ts+3
Ts+5
1h
1h
DB98_20402A(1)_1 10/26/04 2:58 PM Page 75