11
3. Disassembly and Reassembly
3-2 Replacement of High Voltage Trancefomer
Parts Explaination Photo Explaination
High Voltage
Transformer
3. Remove the mounting bolts.
4. Replace the High Voltage
Transformer
5.
After replace, reconnect the
leads correctly and rmly.
PRECAUTION
Servicemen should remove their watches whenever working close to or replacing the magnetron.
PRECAUTION
There exists HIGH VOLTAGE ELECTRICITY with high current capabilities in the circuits of the
HIGHVOLTAGE TRANSFORMER secondary and lament terminals. It is extremely dangerous to work on
or near these circuits with the oven energized.
DO NOT measure the voltage in the high voltage circuit including lament voltage of magnetron.