16
4. Troubleshooting
Weight Sensor
Error
Code
Gas Sensor Error Case (E-1X) Solution Page
E-31 Open (When value of HEX is above “FF” for 5 seconds)
Check Sensor.
17 Page
E-32 Short 18 Page
E-33
In case the initial value of HEX is under “14” for 30
seconds while a weight sensor in operation.
21 Page
E-34
In case the initial value of K calculated by a weight
sensor is above and under “±28” as value of HEX.
E-35 In case the value of A is “-” as a weight sensor calculates.
E-36 In case the door opens during sensor cooking.
Cancel the present mode and
restart from the begining.
22 Page
Easy/Ph Sensor
Error
Code
Easy/PH Sensor Error Case (E4) Solution Page
E-41 Open
Check Sensor.
17 Page
18 PageE-42 Short
E-43 T1 Max Time Error
19 Page
E-44 Dry Up Insert food and restart. 19 Page
E-45 Cooling Error (3minutes) Remove moisture from sensor and restart. 23 Page
E-46 Primary Open Error(3minutes) Check Sensor. 17 Page
E-47 The door opens during cooking
Cancel the present mode and restart from the
begining.
22 Page
Humidity Sensor
Error Code Humidity Sensor Error Case (E-6X) Solution Page
E-61 Open
Check Sensor.
17 Page
E-62 Short 18 Page
E-63 T1 Max Time Error 19 Page
Others
Error
Code
Others (E-0X, Letter) Solution Page
-SE- Key Short Error (10 seconds) Turn off set and restart. 20 Page
E-02 Cooking Time Setting Over Error (MWO)
Check each mode’s setting time.
26 Page
E-03 Cooking Time Setting Over Error (Grill)
E-04
Cooking Time Setting Over Error
(Convection)
E-05
Cooking Time Setting Over Error
(Combination)
E-06
It fails to sense that the swing heater has
stopped for 20 seconds during cooking.
Check Swing heater’s motor and connector. 29 Page