EasyManua.ls Logo

Samsung MW73VR - Preheating Function Error Diagnosis

Samsung MW73VR
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
25
4. Troubleshooting
: Check the voltages of
both heater terminals.
: After operating the heater for more then
10 minutes check if the heater temperature
remains low.
: A normal heater’s resistance is a few Ω.
A short circuit increases the resistance
to a few MΩ.
YES
YES
NO
NO
NO
YES
YES
NO
YES
NO
“E-23, E-26” is displayed.
Is the heater temperature
very low?
Is the temperature sensor
connected properly?
Is the resistance
between the heater terminals
more then a few MΩ?
Check the heater
related drive part.
Replace the
heater.
Reconnect the
temperature
sensor properly.
Replace the
heater.
Does the heater work?
S/W Error
After Power > On,
does the symptom continue?
Replace the PCB.
Perform the operation again and check if it
is working properly.
4-3-9 Preheating Error

Related product manuals