16
PRODUCT SPECIFICATIONS
Items
Model
Defrost Heater(FRE)
Defrost Heater(REF)
DISPENSER Heater
FRENCH Heater
ICE Duct Heater
Water Tank Heater
Interlock with French Heater
-
Interlock with Defrost Heater (FRE)
-
Running
Starting
Model
Operation
Model
Temp.ON
Temp.OFF
Condenser for COMP
(Package type)
Starting-Relay
Over load Relay
Rated Voltage
MOTOR-BLDC(FRE)
MOTOR BLDC(ICE ROOM)
MOTOR-BLDC(REF)
MOTOR-BLDC(CIRCUIT)
MOTOR-DAMPER(PANTRY)
Lamp(FRE)
Lamp(REF)
Conducting af F Defrost
Conducting at R Defrost
Door Switch
FRE
REF
REF(ICE ROOM)
Power cord
Earth Screw
Bimetal thermo For Preventing Overheating of Refrigerator Lamp
AC 115V, 240W / AC 230V, 240W
AC115V, 120W / AC 230V, 120W
AC115V, 3W / AC 230V, 3W
AC115V, 10W / AC 230V, 10W
AC115V, 4W / AC 230V, 4W
DC 12V, 2W
AC125V 10A / AC250V 3A Off: 140 (60 )/ On : 104 (40 )
12 ,250V / 5 ,450V
-
J531Q33E100M200-2
10 20%
4TM435RFBYY-53
266 41 130 5
141.8 48.2 61 9
AC 115V/60Hz / 220~240V/50Hz
DC12V / FDQT06SS3
DC12V / DREP5020LB
DC12V / FDQT06SS3
DC12V / FDQT04SS2
DC12V / NSBY001TA1
AC 120V / 60W(1EA) / AC 230V 40W(1EA)
AC 120V / 60W(2EA) / AC 230V 60W(2EA)
AC 125V 1.5A (1EA) / AC 250V 0.5A
DC200V 1.5A / MS-406-SS-01(2EA)
125~250V /11A, EMB606
AC125V 15A / AC 250V 10A
BSBN (BRASS SCREW)
Specification
RF267AA / RF26DB
Electric Components