11
Electricparts
Items
F-room defrost heater
Condenser for
Comp.(monolithic)
Running
Start
Type
Action
Type
ON temperature
OFF temperature
Start relay
Overload relay
L.V.T(LOW VOLTAGE TRANSFORMER)
F room cooling fan motor
Comp. Cooling fan motor
Freezer interior light
Refrigerator interior light
Door switch
Supply cord
Grounding screw
R-room cover damper
R room electrically driven damper
F room heater sub
F room heater glass
Conducting at F defrosting
Conducting at F defrosting
Conducting at F defrosting
200W
60W
130W
3W
1W
Specification
Initial resistance: 68Ω±20% (Ambient temperature : 25℃)
130 ± 5℃
69 ± 9℃
DC 12V DREP3030LA 0.3A
DC 12V DRCP3030LA 0.24A
AC 250V 0.5A
2EA
TO BE FOLLOWED LOCAL STANDARD
BSBN (Bronze screw)×4EA
250VAC,12㎌
-
J531Q32E4R7M1802
250VAC,12㎌
-
J531Q32E4R7M1802
350VAC,5㎌
-
J531Q34E220M3502
350VAC,5㎌
-
J531Q34E220M3502
350VAC,5㎌
-
J531Q35E330M3852
4TM437RHBYY-53
4TM437RHBYY-53
4TM317SHBYY-53
4TM317SHBYY-53
4TM265RHBYY-53
110 115V/60Hz
127V/60Hz
220V/50Hz
230
240V/50Hz
30W (110 127V)
30W (110 127V)
25W (220 230V)
25W (220 230V)