EasyManua.ls Logo

Samsung RS20NCSW - The Change of Lamp Displays Test Mode Function; Forced Running

Samsung RS20NCSW
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
2) The change of lamp displays test mode function(Pressing for 7 seconds)
3) Forced running
At the time of test mode selection : Lamp all OFF At the time of forced running selection : 8 lamps ON
At the time of forced defrost(1) selection : 5 lamps of
freezer control ON
At the time of forced defrost(2) selection : 5 lamps of
refrigerator control ON
At the release of test function : Lamp all OFF
At the test mode, once more pressing the F room key selects forced running. At this time, buzzer performs alarm by
beep.
If the forced running is selected, compressor is in action immediately without 5 minutes delay action. If defrost is
proceeded at this time, defrost stops immediately.
If the forced running is selected, compressor and F-fan is operated on pull down for 24 hours, and R room is controlled
by set temperature.
The forced running is performed continuously until the completion(24 hours) or change to another mode, or release..
If the forced running is selected, freezer is selected to “ colder(-25 )” , and refrigerator “ middle colder(2 )”
After the forced running is completed(24 hours), defrost is performed regardless of the former mode.
If the forced running is released, Comp. on time during the forced running is reflected in a defrost period by addition.