Defrost Control From 16 to 40 hrs
Defrost Thermistor(502AT) 8
(off)
Electrical Rating H(115V/60Hz) ·····························11.6
Amps
(220V/60Hz)
Maximum Current Leakage 0.25 mA
Maximum Ground Path Resistance 0.1 Ohm
Energy Consumption 580kwh/yr (RS261M)
610kwh/yr (RS26DD)
Ambient Temperature .............. 21
32
Refrigerator,ºC ...........................0~8 0~8
Freezer,ºC .........................
-23~-14 -23~-14
Run Time,% ............................
40 60
Refrigerant Charge (R134a) ..................
7.41 oz
Compressor ................ 888.9 B tu/hr (RS261M)
1,024 B tu/hr (RS26DD)
Compressor oil .............................
Freol α -10
Capillary tube(Dia, Length) ...........
0.033,130
Dryer ................................
Molecular Sieve XH-9
Clearance must be provided for air circulation
AT TOP .....................................................
2"
AT SIDES ..................................................
2"
AT REAR ...................................................
2"
RS261M
**,
RS26DD
**
Main PCB ASSY(Dispenser with Coolzone (America))
..........
DA41-00546A
Main PCB ASSY(Dispenser (America))
........................
DA41-00546B
Main PCB ASSY(Dispenser with Coolzone (Canada))
..........
DA41-00546C
Main PCB ASSY(Dispenser (Canada))
..................
DA41-00546D
Thermistor(Freezer)
.............................................
DA32-10109W
Thermistor(Freezer Evaporator)
...........
DA41-00006B
Thermistor(Refrigerator)
................................
DA41-10109W
Thermistor(Refrigerator Evaporator)
......
DA41-00006D
Thermistor(Ambient)
............................................
DA32-10109V
Thermistor(Coolselect Zone
TM
)
.................
DA32-10109X
Thermistor(Ice-Maker)
.......................................
DA32-10108B
Relay
........................................................................................
DA35-00103B
DA 35-00008X
DA34-10003S
Run Capacitor (12)
............................................
2501-001045
Fan-Motor(FRE)
.........................................................
DA31-00146E
Fan-Motor(REF)
.........................................................
DA31-00146E
Fan-Motor(Condenser)
....................................
DA31-00146B
FanFan
FanFan
(Air inlet)(Air inlet)
(Air inlet)(Air inlet)
Heat exchangerHeat exchangerHeat exchanger
2-2) Specifications
2. PRODUCT SPECIFICATIONS
Compressor
C-FanDryer Electric box
Sub-condenser
ELECTRICAL SPECIFICATIONS Freezer Refrigerator
NO LOAD PERFORMANCE
REFRIGERATION SYSTEM
INSTALLATION
MODELS
REPLACEMENT PARTS