58 | SAMSUNG
FEATURES & OPERATION
6
Details for Operation Property (cont.)
6-2-12. Low Temp Release
AT COOLING MODE
If the temperature of indoor heat exchanger is below -1°C for over 6 minutes, the outdoor fan turns off.
If the temperature of indoor heat exchanger increase over 5°C during the first protection function, the first freezing protection
function is released and the outdoor fan turns on.
If the temperature of indoor heat exchanger increase over 0°C during 6 minutes counting, 6 minutes counter is cleared.
If the temperature of indoor heat exchanger maintains for a minute at -4°C during the 6 minutes counting, switch off the
compressor.
If the compressor is off by Low Temp. Release, 5 minutes release is impossible.
Operating Pattern
Indoor Heat exchanger Temp.(˚C)
5[˚C]
0[˚C]
-1[˚C]
6min
COUNT
ON
COUNT
ON
COUNT
OFF
6min
6min Low temp.
release
ON
Low temp.
release
OFF
6min
3sec
2sec
ON ONOFF
ON ONOFF
Setting Fan speed Setting Fan speed"LL"
COMP_or
Outdoor FAN
Indoor FAN
LL = Low FAN speed 35rpm