4.Troubleshooting
ADFAdjustment
•Diagnostics>Adjustment>ADFAdjustment>ManualAdjustment
PurposeTocorrectimagepositionandmagnicationofscannedimagesmanually.
OperationProcedure
1)Chooseoneitemfromthetable.Therearethreeitemstochoose.
•ImagePosition-LeadingEdge(Unit:mm,Scale:0.1,Min/Max:-3.0/+3.0)
•ImagePosition-SideEdge(Unit:mm,Scale:0.1,Min/Max:-3.0/+3.0)
•Magnication-V erticalDirection(Unit:%,Scale:0.1(0.42mm),Min/Max:98.5/101.5)
2)Selectoneitemandpressthe“Edit”button.
3)Changetheadjustmentvaluewitharrowbutton.
4)ImagePosition(a,b):Ifthecurrentvalueissmallerthanthespecication,press“+”.
Otherwise,press“-”.
5)Magnication(c):Ifthecurrentvalueissmallerthanthespecication,press“-”.Otherwise,
press“+”.
6)Pressthe“OK”buttontoapplythenewvaluetothesystem.
7)ScantheScannerA/SChartandsendittoaPC.ScanningmustbeoccurfromtheDSDF.
8)Tochecktheimageposition,comparethepositionofscalemarks(a,b)ofthecharttothe
copy.
9)Tocheckthemagnication,comparethelengthofline“c”ofthecharttothecopy.
NOTE
Specication
•a,b:10,±1.5mm
•c:190,±1.5mm
4-45Copyright©1995-2013SAMSUNG.Allrightsreserved.