Adjustment
7-7 CCD defect ADJ
<Adjustment method>
1. Save the applicable adjustment le to the memory card.
2. After inserting the memory card containing the program le, turn on the power of the camera.
3. The adjustment will automatically start.
q Check the set reference level, exposure time and loop, and execute the Defective Pixel calibration.
w Refer to the specication (Maximum number of defective cells) and execute the check.
e Refer to the CARD WRITE information to write the number of defective cells to the data le.
4. When the adjustment is completed, the camera will automatically be turned off.
<Adjustment result>
On the memory card, open and check if a CSV le was generated from the adjustment.
Calibrate the Defective pixel of CMOS for each camera.
7-8 OIS centering ADJ
<Adjustment method>
1. Save OIS .hex le and script le on memory card.
2. Install memory card with a program le and then, turn the camera on.
3. Adjustment is made automatically.
OIS module will be operated left/right/up/down 2-3 times.
4. When the adjustment is completed, the camera will be off automatically.
<Adjustment result>
On the memory card, open and check if a CSV le was generated from the adjustment.
Process to check if OIS performs well or not.
CAUTION
!
Put your camera, face up, on a steady surface such as a table or anything solid that won’t move.
Don’t put your camera on a highly unstable surface. Also don’t put your camera down or hold it.
The noise may signicantly affect degrading the Gyro Sensor and Hall Sensor performance.
Light source box
Tripod
Camera