24 _ Troubleshooting
Check Type Check Mode Causes Corrective Actions Description of Photo
Water Supply
Check
►4C
This may occur when the
water supply valve is
defective.
• Ifthewatersupplyvalveisbroken,replace
the valve.
• Checkifthewatersupplyisblockeddue
toanaliensubstanceinthevalveorcheck
if the water is supplied to the machine. If
aproblemisfound,taketheappropriate
countermeasure.
• Checkifthewatersupplyisblockeddueto
the water being frozen.
• IfthePBARelaymalfunctions,replacethe
PBA.
1. Measure the resistance of the
water supply valve.
- Resistance:0.9KΩto1.1KΩ
between the terminals of the
Water Supply Valve.
2. Checkwhetherthereisforeign
material in the Water supply
valvelter.
This may occur when the
main PCB is defective.
This may occur due to
frozen water.
DrainCheck ►5C
This may occur when the
drain pump is defective.
• Checkifthereisanyaliensubstanceinside
the draining pump motor.
• Checkthenaturaldraininthesamemanner.
• Checkifthereareanyincorrectconnections
orbrokenwires.
• Ifthemachinemalfunctionsintermittently
when the wash tub water temperature is
high,replacethepump.
• Ifthemotorstopsduetothewaterbeing
frozeninwinter,removethefrozenwater
referring to the relevant repair procedures.
Checkthedrainpumpresistance.
(Resistance:13.5~16.5Ω)
This may occur due to
frozen water.
Checkifthereisanyalien
substance inside the
draining pump.
This may occur when the
main PCB is defective.
Communication
Check
►AC
The signals between the sub
andmainPBAsarenot
sensed.
• Checkthewireconnectionsandterminal
contactsbetweenthesubandmainPBAs.
• Checkfordisconnectedwires.
• CheckwhetherthesubPBAisshort-circuited
because of moisture.
• IfthemainPBAscommunicationcircuitis
faulty,replaceit.
-
Incorrect wire connections
between the sub and main
PBAs.