Troubleshooting _ 27
Symptom Check Code Countermeasure Troubleshooting Procedure Measurement Picture
HeaterCheck
►HC
HC1
• Disconnectionwire
• Heaterfalut
• Wash-thermistorfault
• Checkforconnectionbetweenwireand
heater.
• Ifwashheaterisfaulty,replaceit.
- RefertheTYPE1
• Ifitisnotprobleminheater,replacewash-
thermistor
- RefertheTYPE2
-
Temperature
SensorCheck
►TC1
TC2
TC3
TC4
•Washingtemperature
sensor fault
•Drytemperaturesensor
fault
•Faultyandincorrect
connections of the dry
condensing sensor
•MainPCBfault
•Freezinginthewinter
season
•IPMtemperatureis
abnormally high.
•Checktheconnectionsforthewashing
heater temperature sensor connector.
•Ifthewashingheatertemperaturesensorhas
afunctionalerror,replaceit.
-ATC1checkoccurs.
•Checktheconnectionsforthedryheater
temperature sensor connector.
•Ifthedryheatertemperaturesensorhasa
functionalcheck,replaceit.
-ATC2checkoccurs.
-
PowerCheck
►UC
(9C1/9C2)
•Powerconditionfault.
•Ancheckoccurswhen
under or over voltage is
supplied.
•plugreceptacleisused
•MainPBAfault
(sometimes)
•Checktheconsumer’spowerconditions.
:Makesuretochecktheoperatingvoltage.
•Connectatestertotheinternalpower
terminals during the Boil or Dry operations
andobservethewashingmachine’s
operation carefully.
:Checkthevoltages.(Acheckoccurswhen
underorovervoltageissupplied.)
:Checkwhetheraplugreceptacleis
used.Whentheconnectingwireis1m,a
momentary low voltage may drop up to 10 V
•MainPBAfault(sometimes)
-